DG-PR Series

Dalgakiran DJ-PR series based on Perkins diesel engines. Large range of models from 9 to 2000 kVA.
Perkins (United Kingdom) as one of the world’s leading providers of diesel engines we are passionate about delivering excellent products and services that exceed our customers’ expectations. With manufacturing facilities operating around the globe, Perkins have the capacity to produce up to 800,000 units a year.

MODELS AND TECHNICAL INFORMATION

Based on Leroy Somer alternator

ModelEngineAlternatorPowerDimensions (mm)WeightFuel tank
Standby Power (ESP)Prime Power (PRP)CanopiedOpen SkidCanopiedOpen SkidCanopiedOpen Skid
kVAkWkVAkWWHLWHLkgkgliterliter
DJ10PR403A-11G1TAL040B10897.270012501000700175012003184857575
DJ14PR403A-15G1TAL040D1411.21310.470012501000700175012003324997575
DJ22PR404A-22G1TAL040F2217.6201670013501050700175012003975647575
DJ33PR1103A-33GTAL042C3326.4302495016501220950220014507049789090
DJ50PR1103A-33TG1TAL042F50404536950165012209502200145076710419090
DJ66PR1103A-33TG2TAL042H6652.8604895020001230950265014508131127160160
DJ72PR1104A-44TG1TAL044B7257.66552950200012309502650145010181332160160
DJ88PR1104A-44TG2TAL044B8870.48064950200012309502650145010181332160160
DJ100PR1104C-44TAG2TAL044C100809072950200012509502650145010511365160160
DJ110PR1104C-44TAG2TAL044D1108810080950200012509502650145010511365160160
DJ150PR1106A-70TG1TAL044H15012013510811002350135011003320160014541875260260
DJ165PR1106A-70TAG2TAL044J16513215012012002700147012003860185015952136330330
DJ182PR1106A-70TAG3TAL044K182145.6166132.812002700147012003860185016302171330330
DJ200PR1106A-70TAG3TAL044L20016018014412002700147012003860185017662307330330
DJ220PR1106A-70TAG4TAL044M22017620016012002700147012003860185017962337330330
DJ248PR1206A-E70TTAG2TAL046C248198.4224179.212002700173012003860185019032444330330
DJ270PR1206A-E70TTAG3TAL046D270216248198.412003000163012003860185019112452330330
DJ303PR1506A-E88TAG4TAL046E303242.427522013003000168013003940185027403305330385
DJ343PR1506A-E88TAG5TAL046G343274.4314251.213003000168013003940185028743439385385
DJ400PR2206A-E13TAG2TAL046H40032035528416503300205016505000225032854271900900
DJ450PR2206A-E13TAG3TAL047A45036040532416503300205016505000225033734359900900
DJ500PR2506A-E15TAG1TAL047B50040045536416503500205016505360225037814846970970
DJ550PR2506A-E15TAG2TAL047C55044050040016503500205016505360225037814846970970
DJ600PR2806A-E18TAG1ATAL047D60048055044016503500216016505360245040585199970970
DJ660PR2806A-E18TAG1ATAL047E66052860048016503500216016505360245041075248970970
DJ680PR2806A-E18TAG1ATAL047F680544618494.416503500216016505360245041905331970970
DJ721PR2806A-E18TAG2TAL047F721576.866052816503500216016505360245041905331970970
DJ804PR2806A-E18TTAG5TAL049B8056447305841700340023302200582024004833754810801600
DJ841PR2806A-E18TTAG5TAL049C841672.8763610.41700340023302200582024004894760910801600
DJ805PR4006-23TAG2ATAL049B8056447305841700370022852200582024005787838711351600
DJ886PR4006-23TAG3ATAL049C886708.8794635.21700370022852200582024005848844811351600
DJ1000PR4008TAG1ATAL049E1002801.69107282050466023702200582024007394982415401540
DJ1100PR4008TAG2TAL049E110088010008002050466023702200582024007394982415401540
DJ1250PR4008-30TAG3LSA50.2M612521001.61123898.420504660230022005820240080471047715401540
DJ1375PR4012-46TWG2ALSA50.2M613751100125010002050453524702470608029009493131831540N/A
DJ1485PR4012-46TWG3ALSA50.2L714851188135010802050460026402470608029009763134531540N/A
DJ1500PR4012-46TWG3ALSA50.2L815031202.413671093.62050460026402470608029009983136731540N/A
DJ1650PR4012-46TAG2ALSA50.2L816501320150012002250500024202470914531009934160142500N/A
DJ1800PR4012-46TAG3ALSA50.2VL10180014401640131222505000280024709145315010404164843500N/A
DJ1900PR4012-46TAG3ALSA52.3S519021521.617331386.422505130280024709145315010849169293500N/A
DJ2020PR4016-61TRG1LSA52.3S520171613.618601488225060002560247012220315011801194213500N/A
DJ2200PR4016-61TRG2LSA52.3S62200176020001600225060002560247012220315011821194413500N/A
DJ2270PR4016-61TRG2LSA52.3S722681814.420171613.6225060002560247012220315012066196863500N/A
DJ2500PR4016-61TRG3LSA52.3L92500200022501800225060002750247012220315012705202253500N/A

Based on Crompton Greaves alternator

ModelEngineAlternatorPowerDimensions (mm)WeightFuel tank
Standby Power (ESP)Prime Power (PRP)CanopiedOpen SkidCanopiedOpen SkidCanopiedOpen Skid
kVAkWkVAkWWHLWHLkgkgliterliter
DJ9PR403A-11G1G1R160C1E97.286.47001250950700175012003304977575
DJ14PR403A-15G1G1R160C2B1411.2129.670012501000700175012003415087575
DJ21PR404A-22G1G1R160C3B2116.81915.270013201050700175012004035707575
DJ33PR1103A-33GG1R160C5A3326.4302495016501220950220014507129869090
DJ44PR1103A-33TG1G1R200SE4435.24032950165012209502200145074810229090
DJ50PR1103A-33TG1G1R200SA5040453695020001230950265014508341148160160
DJ66PR1103A-33TG2G1R200SC6652.8604895020001230950265014508721186160160
DJ73PR1104A-44TG1G1R200MB7358.46652.8950200012309502650145010521366160160
DJ83PR1104A-44TG2G1R200MB8366.47560950200012309502650145010521366160160
DJ89PR1104A-44TG2G1R200MD8971.28164.8950200012309502650145010911405160160
DJ110PR1104C-44TAG2G1R250SB110881008011002350125011003320160011861607260260
DJ138PR1106A-70TG1G1R250SD138110.412510011002350135011003320160014971918260260
DJ150PR1106A-70TG1G1R250MA150120136108.811002350135011003320160014971918260260
DJ166PR1106A-70TAG2G1R250MB166132.8151120.812002700147012003860185016772218330330
DJ204PR1106A-70TAG3G1R250LD204163.2184147.212002700147012003860185017472288330330
DJ220PR1106A-70TAG4G1R250LD22017620016012002700147012003860185017472288330330
DJ252PR1206A-E70TTAG2G1R315SE252201.6234187.213003000163013003940185027053270385385
DJ275PR1206A-E70TTAG3G1R315SE27522025020013003000163013003940185027053270385385
DJ312PR1506A-E88TAG4G1R315SB312249.628522813003000168013003940185029393504385385
DJ341PR1506A-E88TAG5G1R315SB342273.6312249.613003000168013003940185029393504385385
DJ406PR2206A-E13TAG2G1R315MB406324.8356284.816503300205016505000225034264412900900
DJ440PR2206A-E13TAG3G1R355SB44035240032016503300205016505000225035114497900900
DJ511PR2506A-E15TAG1G1R355SE512409.6466372.816503500205016505360225040215086970970
DJ550PR2506A-E15TAG2G1R355SE55044050040016503500205016505360225040215086970970
DJ674PR2806A-E18TAG1AG1R355MA676540.861549216503500216016505360245044255566970970
DJ717PR2806A-E18TAG2G1R355MB719575.2667533.616503500216016505360245043585499970970
DJ843PR2806A-E18TTAG5G1R400SC843674.4752601.61700340023302200582024005055777010801600
DJ815PR4006-23TAG2AG1R400SC815652742593.61700380022852200582024006009860911351600
DJ902PR4006-23TAG3AG1R400MA904723.2808646.41700380022852200582024006503910311351600
DJ1000PR4008TAG1AG1R400MA1004803.2913730.420504500237022005820240078471027715401540
DJ1100PR4008TAG2G1R400MA1110888101080820504500237022005820240078471027715401540
DJ1250PR4008-30TAG3G1R400ME12501000110088020504500230022005820240080001043015401540
DJ1400PR4012-46TWG2AG1R400MB13931114.4125010002050470024702470608029009536132261540N/A
DJ1500PR4012-46TWG3AG1R450SB1500120013641091.22050480026402470608029009763134531540N/A
DJ1650PR4012-46TAG2AG1R450SC1650132015121209.62250500024202470914531009972160522500N/A
DJ1900PR4012-46TAG3AG1R450MA18911512.81720137622505130280024709145315010462165423500N/A
DJ2020PR4016-61TRG1G1R450LA20231618.418721497.6225060002560247012220315011936195563500N/A
DJ2200PR4016-61TRG2G1R450LA2200176020231618.4225060002560247012220315011956195763500N/A
DJ2500PR4016-61TRG3G1R450LB2500200022001760225060002750247012220315012299198193500N/A

General Information

The maximum power which a generating set is capable of delivering continuously whilst supplying a constant electrical load. Average load can be 100%. The generator must not be overloaded.

The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 hrs of operation per year under average of 70% load. Overloading isn’t permissible.

The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs/

In Dalgakiran generator sets, leading engine brands that have state of the art technologyand have compliance with ISO 8528, ISO 3046, BS 5514, DIN 6271 standarts, are being used. These engines with low fuel consumption, provide accurate speed setting and order, mount to the fuel pump, also have mechanic or electronic type governors.

In products Dalgakiran produced, leading alternator brands of the world that have state of the art technology, high quality, productivityand durability, are being used. All alternators, which pass necessary test process and found appropriate according to EC 60034-1; CEI EN 60034-1; BS 4999-5000; VDE 0530, NF 51- 100,111; OVE M-10, NEMA MG 1.22.standarts, have bearing system that does not need maintenance, with electronic type voltage regulator providing voltage setting.

Standard control panel, that is used in Dalgakiran generator sets, ensures comfortable and safe usage. All measured and statistical parameters, operating modes, notice and alarms and condition of generator, are monitored easily from the control panel. On the front of the panel’s metal bodyhas electronic control module and the emergency stop button and the panel’s metal body is made of steel sheet and is painted with electrostatic powder paint. Dalgakiran offers panel design and solutionsthatcomply with special requirements ofcustomersas wellas qualitystandard panels.

Chassisis manufactured from steel that has featuresand durability forcarrying burden of generatorset. Thanks to its rigid structural design and anti-vibration mounts, it reduces vibration level to minimum. All chass is contain lifting lugs. Apart from chass is esthatare produce by Dalgakiran, special solutions that design in accordance with customer desires, make transportation and positioning easier.

System, that consists of quality industrial – type radiator, expansion tank and cooler fan, keeps the temprature of generator set’s equipments constant at a proper level.

Some Optional Equipments that Dalgakiran provides with Generator Sets;

  • Medium voltage alternator,
  • Remote radiator applications,
  • Automatic fuel filling system,
  • Fuel tank, oil pan, dashboard,alternator, coil heaters,
  • Alternator with double AVR and PMG,
  • Synchronization systems,
  • The generator output breaker,
  • Grid-generator transfer switches,
  • Accordance with the specific volume of demand-insulated cabins,
  • Seismic solutions,
  • Trailer,
  • Remote monitoring.

Dalgakiran Standard Canopies’ default featuresare as follows;

  • Compatible with 2000/14/EC directives, certified noise emissionlevel,
  • 2 or 4 points transport possibility according to cabin size,
  • Hidden exhaust inside the canopy,
  • Emergency stop button located on the canopy,
  • Improved air suction channel to ensure homogenous cooling in the canopy,
  • Radiator air outlet and exhaust with designed towardsabove,
  • Lid on cab that provides to be filled up water and antifreeze easilyto the radiator,
  • Amplified paint system against corrosion and rust,
  • Improved performance in terms of sound insulation,
  • Demounted parts that make transportation and maintenance easier,

As well as the standard range of canopies, Dalgakiran can also design tailormade canopies with specific sound level or size upon customer requests

  • The Control Panel is a next generation genset control unit combining multi-functionality and wide communication possibilities together with a reliable and low cost design.
  • The unit complies and mostly exceeds world’s tightest safety, EMC, vibration and environmental standards for the industrial category.
  • Software features are complete with easy firmware upgrade process through USB port. The Windows based PC software allows monitoring and programming through USB, RS-485, Ethernet and GPRS.
  • The PC and server based Rainbow Scada software allows monitoring and control of an unlimited number of gensets from a single central location.
  • AMF unit with uninterrupted transfer
  • ATS unit with uninterrupted transfer
  • Remote start controller
  • Manual start controller
  • Engine controller
  • Remote display & control unit
  • Waveform display of V & I
  • Harmonic analysis of V & I
  • CTs at genset or load side
  • SM-GPRS
  • Web monitoring
  • Web programming
  • GSM-SMS
  • e-mail
  • USB Device
  • RS-232
  • J1939-CANBUS
  • 2 phase 3 wires, L1-L2
  • 2 phase 3 wires, L1-L3
  • 3 phase 3 wires, 3 CTs
  • 3 phase 3 wires, 2 CTs (L1-L2)
  • 3 phase 3 wires, 2 CTs (L1-L3)
  • 3 phase 4 wires, star
  • 3 phase 4 wires, delta
  • 1 phase 2 wires
Scroll Up