Minimizes energy losses with very low differential pressure.
Positive seal ensures best sealing.
Filter change pressure difference 170 mbar.
Long service life.
MODELS AND TECHNICAL INFORMATION
MODEL | Capacity | Connection Size | Drain Port | Maximum Working Pressure |
Maximum Working Temperature |
Element Model | Housing Dimensions (mm) | ||||||||
m3/min | cfm | Size | bar | 0C | A | B | C | D | OE | OE | G | H | |||
ELM 150 | 4.25 | 150 | DN50 | G ½” | 16 | 80 | 14 | 500 | 1003 | 209 | 459 | 203 | 103 | 305 | 330 |
ELM 300 | 8.5 | 300 | DN50 | G ½” | 16 | 80 | 14 | 500 | 1105 | 209 | 559 | 203 | 103 | 407 | 435 |
ELM 600 | 17 | 600 | DN50 | G ½” | 16 | 80 | 14 | 500 | 1461 | 209 | 916 | 203 | 103 | 762 | 790 |
ELM 800 | 22.7 | 800 | DN80 | G ½” | 16 | 80 | 14 | 500 | 1655 | 279 | 1084 | 203 | 103 | 915 | 950 |
ELM 1200 | 34 | 1200 | DN80 | G ½” | 16 | 80 | 14 | 600 | 1520 | 281 | 931 | 254 | 103 | 762 | 790 |
ELM 1600 | 45.3 | 1600 | DN80 | G ½” | 16 | 80 | 14 | 600 | 1671 | 281 | 1086 | 254 | 103 | 915 | 950 |
ELM 2100 | 59.5 | 2100 | DN100 | G ½” | 16 | 80 | 14 | 700 | 1575 | 335 | 953 | 300 | 129 | 762 | 790 |
ELM 2750 | 77.9 | 2752 | DN100 | G ½” | 16 | 80 | 14 | 700 | 1726 | 335 | 1100 | 300 | 129 | 915 | 950 |
ELM 4200 | 119 | 4200 | DN150 | G ½” | 16 | 80 | 14 | 800 | 1670 | 393 | 983 | 365 | 181 | 762 | 790 |
ELM 6000 | 170 | 6000 | DN150 | G ½” | 16 | 80 | 14 | 800 | 1925 | 393 | 1258 | 365 | 181 | 950 | 1045 |
ELM 8000 | 226.7 | 8000 | DN200 | G ½” | 16 | 80 | 14 | 850 | 2020 | 417 | 1277 | 386 | 233 | 1016 | 1045 |
ELM 10000 | 283.3 | 10000 | DN250 | G ½” | 16 | 80 | 14 | 1000 | 2118 | 417 | 1307 | 407 | 337 | 1016 | 1045 |
ELM 12000 | 340 | 12752 | DN300 | G ½” | 16 | 80 | 14 | 1000 | 2688 | 497 | 1847 | 437 | 337 | 1524 | 1550 |
General Information
Possible filter blockage or damage of the compressor oil seperator going to the system and prevent the risk of the reliability of the system increases. Extremely easy setup and operation, this product also need to hear the service for a long time.
- Very low pressure loss
- High efficiency separation oil mist
- Easy cleaning
- Standard automatic float drain
- 4 Minimum Maximum Operating temperature of 80 OC to OC
- 0,01 micron particle retention and oil-water mixture included in the aerosol holding ability is 0,01 ppm.
- Extended surface area and allow a more effective separation takes place at low speed, splitting.
- Elements of static electricity that is grounded to the problems of the body are minimized.
To calculate the maximum flow rate coefficient multiply catalog working pressure corresponding to the flow rate.
- Minimizes energy losses with very low differential pressure
- The positive gasket seal provides the best way to
- Change the filter 170 mbar pressure difference
- Long service life