Ford Otosan, is a publicly traded company, where Ford Motor Company and Koç Holding A.Ş. have equal shares. Ford Otosan, established in 1959, with its production capacity of 455,000 commercial vehicles and 70,000 engines and 140,000 powertrains by the end of 2019, is the biggest commercial vehicle production center of Ford in Europe. Ford Otosan has the biggest and most capable R&D organisation of the Turkish automotive industry in Turkey with its R&D engineer staff of 1,389 people. Within the evaluation carried among the plants of Ford Motor Company, Kocaeli and Eskişehir plants are shown as one of the “Best Vehicle Production Centers”.

MODELS AND TECHNICAL INFORMATION

Based on Leroy Somer alternator

Model Engine Alternator Power Dimensions (mm) Weight Fuel tank
Standby Power (ESP) Prime Power (PRP) Canopied Open Skid Canopied Open Skid Canopied Open Skid
kVA kW kVA kW W H L W H L kg kg liter liter
DJ275EC 9G30 TAL046D 275 220 250 200 1650 TBA TBA 1650 4700 2250 TBA TBA 780 780
DJ298EC 9G30 TAL046E 298 238,4 275 220 1650 TBA TBA 1650 4700 2250 TBA TBA 780 780
DJ360EC 13G45 TAL046G 360 288 325 260 1650 TBA TBA 1650 5000 2250 TBA TBA 900 900
DJ400EC 13G45 TAL046H 400 320 365 292 1650 TBA TBA 1650 5000 2250 TBA TBA 900 900
DJ451EC 13G45 TAL047A 450 360 407 325,6 1650 TBA TBA 1650 5000 2250 TBA TBA 900 900
DJ500EC 13G55 TAL047B 500 400 455 364 1650 TBA TBA 1650 5360 2250 TBA TBA 970 970
DJ550EC 13G55 TAL047C 550 440 500 400 1650 TBA TBA 1650 5360 2250 TBA TBA 970 970

General Information

The maximum power which a generating set is capable of delivering continuously whilst supplying a constant electrical load. Average load can be 100%. The generator must not be overloaded.

The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 hrs of operation per year under average of 70% load. Overloading isn’t permissible.

The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs/

In Dalgakiran generator sets, leading engine brands that have state of the art technologyand have compliance with ISO 8528, ISO 3046, BS 5514, DIN 6271 standarts, are being used. These engines with low fuel consumption, provide accurate speed setting and order, mount to the fuel pump, also have mechanic or electronic type governors.

In products Dalgakiran produced, leading alternator brands of the world that have state of the art technology, high quality, productivityand durability, are being used. All alternators, which pass necessary test process and found appropriate according to EC 60034-1; CEI EN 60034-1; BS 4999-5000; VDE 0530, NF 51- 100,111; OVE M-10, NEMA MG 1.22.standarts, have bearing system that does not need maintenance, with electronic type voltage regulator providing voltage setting.

Standard control panel, that is used in Dalgakiran generator sets, ensures comfortable and safe usage. All measured and statistical parameters, operating modes, notice and alarms and condition of generator, are monitored easily from the control panel. On the front of the panel’s metal bodyhas electronic control module and the emergency stop button and the panel’s metal body is made of steel sheet and is painted with electrostatic powder paint. Dalgakiran offers panel design and solutionsthatcomply with special requirements ofcustomersas wellas qualitystandard panels.

Chassisis manufactured from steel that has featuresand durability forcarrying burden of generatorset. Thanks to its rigid structural design and anti-vibration mounts, it reduces vibration level to minimum. All chass is contain lifting lugs. Apart from chass is esthatare produce by Dalgakiran, special solutions that design in accordance with customer desires, make transportation and positioning easier.

System, that consists of quality industrial – type radiator, expansion tank and cooler fan, keeps the temprature of generator set’s equipments constant at a proper level.

Some Optional Equipments that Dalgakiran provides with Generator Sets;

  • Medium voltage alternator,
  • Remote radiator applications,
  • Automatic fuel filling system,
  • Fuel tank, oil pan, dashboard,alternator, coil heaters,
  • Alternator with double AVR and PMG,
  • Synchronization systems,
  • The generator output breaker,
  • Grid-generator transfer switches,
  • Accordance with the specific volume of demand-insulated cabins,
  • Seismic solutions,
  • Trailer,
  • Remote monitoring.

Dalgakiran Standard Canopies’ default featuresare as follows;

  • Compatible with 2000/14/EC directives, certified noise emissionlevel,
  • 2 or 4 points transport possibility according to cabin size,
  • Hidden exhaust inside the canopy,
  • Emergency stop button located on the canopy,
  • Improved air suction channel to ensure homogenous cooling in the canopy,
  • Radiator air outlet and exhaust with designed towardsabove,
  • Lid on cab that provides to be filled up water and antifreeze easilyto the radiator,
  • Amplified paint system against corrosion and rust,
  • Improved performance in terms of sound insulation,
  • Demounted parts that make transportation and maintenance easier,

As well as the standard range of canopies, Dalgakiran can also design tailormade canopies with specific sound level or size upon customer requests

  • The Control Panel is a next generation genset control unit combining multi-functionality and wide communication possibilities together with a reliable and low cost design.
  • The unit complies and mostly exceeds world’s tightest safety, EMC, vibration and environmental standards for the industrial category.
  • Software features are complete with easy firmware upgrade process through USB port. The Windows based PC software allows monitoring and programming through USB, RS-485, Ethernet and GPRS.
  • The PC and server based Rainbow Scada software allows monitoring and control of an unlimited number of gensets from a single central location.
  • AMF unit with uninterrupted transfer
  • ATS unit with uninterrupted transfer
  • Remote start controller
  • Manual start controller
  • Engine controller
  • Remote display & control unit
  • Waveform display of V & I
  • Harmonic analysis of V & I
  • CTs at genset or load side
  • SM-GPRS
  • Web monitoring
  • Web programming
  • GSM-SMS
  • e-mail
  • USB Device
  • RS-232
  • J1939-CANBUS
  • 2 phase 3 wires, L1-L2
  • 2 phase 3 wires, L1-L3
  • 3 phase 3 wires, 3 CTs
  • 3 phase 3 wires, 2 CTs (L1-L2)
  • 3 phase 3 wires, 2 CTs (L1-L3)
  • 3 phase 4 wires, star
  • 3 phase 4 wires, delta
  • 1 phase 2 wires